Product Description
Schneider Electric LC1D65008 TeSys D Contactor — 4-Pole, 80A, 2NO/2NC
The Schneider Electric LC1D65008 is a 4-pole, 80A IEC contactor from the TeSys D / TeSys Deca line, featuring a 2NO/2NC power pole configuration rated at 80A AC-1 for resistive and non-inductive loads up to 690V. Commonly used in crane and hoist control circuits, reversing duty applications, capacitor bank switching, and 4-wire load control, the LC1D65008 mounts on standard 35mm DIN rail and is fully compatible with TeSys D accessory blocks. For higher current requirements in the same configuration, see the LC1D80008 (125A AC-1).
Quick Specifications
- Current Rating: 80A (AC-1) at 690V
- Poles: 4-Pole (2 N.O. + 2 N.C. power poles)
- Voltage Rating: 690V AC (operating) / 1000V (Ui)
- Coil Voltage: Multiple options — select from 48V to 480V AC (see coil voltage table below)
- Auxiliary Contacts: None built-in (field-mountable LADN/LAD8N blocks available)
- Frame Width: 85mm
- Mounting: 35mm DIN Rail or Screw Mounting
- Terminal Type: Screw Clamp
- Operating Rate: Up to 3600 cycles/hour at 60°C
- Standard: IEC/EN 60947-4-1
Coil Voltage Options
| Coil Voltage | Suffix Code | Full Part Number |
|---|---|---|
| 48V 50/60Hz AC | E7 | LC1D65008E7 |
| 110V 50/60Hz AC | F7 | LC1D65008F7 |
| 120V 50/60Hz AC | G7 | LC1D65008G7 |
| 208V 50/60Hz AC | LE7 | LC1D65008LE7 |
| 220V 50/60Hz AC | M7 | LC1D65008M7 |
| 230V 50/60Hz AC | P7 | LC1D65008P7 |
| 240V 50/60Hz AC | U7 | LC1D65008U7 |
| 440V 50/60Hz AC | R7 | LC1D65008R7 |
| 480V 50/60Hz AC | T7 | LC1D65008T7 |
Typical Applications
| Application | Why 4-Pole 2NO/2NC |
|---|---|
| Crane & Hoist Control | Simultaneous switching of power and control circuits in a single contactor |
| Reversing Duty Circuits | 2NO/2NC configuration supports forward/reverse interlocking logic |
| Capacitor Bank Switching | High AC-1 rating suitable for capacitive load switching |
| 4-Wire Resistive Load Switching | All 4 conductors switched simultaneously including neutral |
| Heating & Lighting Control | 80A AC-1 rating for large resistive loads up to 690V |
Product Features
- 2NO/2NC Power Pole Configuration: The LC1D65008 has 2 normally open and 2 normally closed power poles in a single contactor body, making it suited for crane duty, reversing, and 4-pole switching applications where both opening and closing contacts are required simultaneously.
- 80A AC-1 Rating at 690V: Rated for resistive and non-inductive loads at 80A AC-1 up to 690V. Note: this is an AC-1 rated contactor — it is not rated for AC-3 motor switching at this current level. For motor switching applications, refer to the standard 3-pole LC1D series.
- 85mm Frame Width: The LC1D65008 uses the 85mm TeSys D frame (wider than the 45mm small-frame LC1D09–LC1D32 range). Allow adequate panel space when designing with this contactor.
- High Cycle Rate: Rated for up to 3600 switching cycles per hour at ambient temperatures up to 60°C — suitable for high-frequency switching in crane and automated process applications.
- TeSys D Accessory Compatible: Accepts LADN front-mount and LAD8N side-mount auxiliary contact blocks from the TeSys D range, which snap on without tools.
- Global Certifications: Compliant with IEC/EN 60947-4-1, UL, CSA, CCC, EAC, and Marine standards for domestic and international panel builds.
Stock Item – Order before 4:00 PM EST for Same-Day Shipping.
Frequently Asked Questions
What does LC1D65008 mean?
The part number follows Schneider Electric’s TeSys D naming convention: LC1 = IEC contactor, D = TeSys D frame, 650 = 80A 4-pole variant, 08 = 2NO/2NC contact configuration. The coil voltage suffix is appended at the end — for example, LC1D65008G7 is the 120V 50/60Hz AC version and LC1D65008T7 is the 480V AC version. Select your coil voltage from the dropdown above.
What is the difference between the LC1D65008 and LC1D80008?
Both are 4-pole, 2NO/2NC TeSys D contactors for the same applications — the difference is current rating. The LC1D65008 is rated 80A AC-1 and the LC1D80008 is rated 125A AC-1. Both use the same 85mm frame, the same TeSys D accessories, and the same coil voltage suffix system. Choose the LC1D65008 for loads up to 80A and the LC1D80008 for loads from 80A up to 125A.
Can the LC1D65008 be used for motor starting?
The LC1D65008 is rated at 80A AC-1 for resistive and non-inductive loads — it is not rated for AC-3 direct-on-line three-phase motor starting at this current level. For motor starting applications, use the standard 3-pole LC1D series which carry AC-3 ratings. The LC1D65008 is specifically suited for crane duty, reversing circuits, capacitor switching, and 4-wire resistive load control.
Does the LC1D65008 come with auxiliary contacts?
No — the base LC1D65008 ships without auxiliary contacts. LADN front-mount and LAD8N side-mount auxiliary contact blocks from the TeSys D accessory range snap on without tools and are fully compatible with the LC1D65008.
What frame size is the LC1D65008?
The LC1D65008 uses the 85mm wide TeSys D frame — this is larger than the compact 45mm frame used by the LC1D09 through LC1D32 range. Ensure your panel layout allows for the 85mm width (127mm H × 85mm W × 125mm D) before ordering. If you are replacing an existing unit, confirm the frame size of the installed contactor before ordering.
Is the LC1D65008 in stock for same-day shipping?
Yes — the LC1D65008 is a stocked item at Kent Electrical Supply’s warehouse in Emmaus, PA. Orders placed before 4:00 PM EST ship the same business day. Current stock quantity is shown on this page. If you need a specific coil voltage that shows low or no stock, call us at 1-800-222-5129 or text your RFQ to 484-425-0652.
Other Details
![]() |
Schneider Electric offers a 1 year warranty on this contactor Schneider Electric does not cover reimbursement for labor, removal, installation or any other expense which resulted from the repair or replacement |